Available 23 files for Emulex LPe1150-F4-F
Select Files
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
x86 BootBIOS
Operating System
Boot Code
Version
2.02a2
Size Driver
38KB
File Name
wb202a2.zip
Observations
Support Resources for PRIMERGY Servers
Platform: Intel (32-bit) The adapter boot BIOS provides x86 boot capability through the use of INT13
system BIOS calls. The adapter Boot BIOS supports:
(1) Multi-topology: Fabric Point to Point; FC-AL: Private loop and Public loop
topologies.
(2) Multi-initiators: The adapter BIOS supports up to 32 Emulex LightPulse
adapters in a system.
(3) Multi-LUNs: The adapter BIOS supports up to 256 LUNs.
(4) Multi-boot: The adapter BIOS complies with the BIOS Boot Specification
(BBS).
(5) EDD (Enhanced Disk Drive Services): The adapter BIOS supports both the
EDD 3.0 and EDD 2.1 specifications depending on the selection in the
adapter BIOS configuration utility.
(6) Boot fail over feature: There are eight boot entries that can be
configured in the adapter BIOS configuration utility. If the first boot
entry fails the system is still able to boot from the second configured
boot entry and so on.
\2.02a2.txt this file you are reading
\DB202a2.PRG Lp8000 adapter boot BIOS version 2.02a2
\CB202a2.PRG Lp9000 adapter boot BIOS version 2.02a2
\HB202a2.PRG Lp9802 adapter boot BIOS version 2.02a2
\TB202a2.PRG Lp10000 adapter boot BIOS version 2.02a2
\BB202a2.PRG Lp11000 adapter boot BIOS version 2.02a2
\QB202a2.PRG Lp850 adapter boot BIOS version 2.02a2
\RB202a2.PRG Lp952 adapter boot BIOS version 2.02a2
\LB202a2.PRG Lp982 adapter boot BIOS version 2.02a2
\MB202a2.PRG Lp1050 adapter boot BIOS version 2.02a2
\JB202a2.PRG Lp1150 adapter boot BIOS version 2.02a2
\EB202a2.PRG Lp101 adapter boot BIOS version 2.02a2
\YB202a2.PRG LPe111 adapter boot BIOS version 2.02a2
\AB202a2.PRG Lp21000 adapter boot BIOS version 2.02a2
\WB202a2.PRG LPe1150 adapter boot BIOS version 2.02a2
\ZB202a2.PRG LPe11000 adapter boot BIOS version 2.02a2
\UB202a2.PRG LPe12000 adapter boot BIOS version 2.02a2
\OB202a2.PRG LPe1250 adapter boot BIOS version 2.02a2
\PB202a2.PRG LPe121 adapter boot BIOS version 2.02a2
***** Important Note ******
(1) BIOS downloading
The adapter boot BIOS image has increased in size to 49K. As a result, it might
fail during the downloading of the BIOS .prg file. One way to correct the
problem is to download the firmware .AWC file WITHOUT the BIOS image
(for example: dd390a7.awc) and then download the adapter boot BIOS .prg file.
(2) BIOS was not activated (Enabled)
If the adapter boot BIOS is not enabled by LP6DUTIL or an Emulex O.S.
configuration utility, the adapter and the drives connected to the adapter
cannot not be configured to be used to boot the system. In addition if there is
a "No BIOS support" message displayed next to this adapter in the adapter BIOS
configuration utility the user must use LP6DUTIL or other Emulex O.S.
configuration utility to enable the adapter boot BIOS in order to allow this adapter
to be used a bootable controller by the host system.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Firmware
Operating System
Firmware
Version
1.11a5
Size Driver
291KB
File Name
wf282a3.zip
Observations
Support Resources for PRIMERGY Servers RELEASE NOTES FOR FIRMWARE VERSION 2.82A3
Date: June 2009
Product: Emulex® LightPulse® adapters: LPe11000, LPe11002, LPe1104, LPe1150, LP11000, LP11002, LP1150 and LPe111
Version:2.82a3 Firmware
This document describes the known issues associated with this firmware build release. For the latest product documentation, go to www.emulex.com. If you have any questions or require additional information, contact an authorized Emulex Corporation technical representative.
New Feature in Firmware Version 2.82a3
Added Host Pointer SLIM (HPS) bit support.
Resolved Issues Firmware Version 2.82a3
1. Improved reset handling.
2. Improved internal retransmission of an FCP command during FC-Tape recovery.
3. Eliminated spurious firmware interrupts[JB4].
4. A word check now correctly verifies that the Abort Sequence frame (ABTS) is the first frame of exchange.
5. Adapters now handle IERR and link down reset automatically.
6. Enhanced handling of multiple split errors. The firmware had previously returned trap code 0x40000005 caused by multiple split errors from the host bus.
7. The N_Port_ID now is handled correctly in REG_VPI after a link down followed by a link up.
8. For LP11000, LP1150, LPe11000 and LPe1150 adapters, the correct VNPid is saved into the entry VPIO when the ELS_REQUEST64 cmd is used with CT= 0 and RPI = 0.
9. Resolved general NPIV issues.
10. The LPe1150 adapter now correctly saves the max_payload_size value across a warm system reboot (PCIE reset).
11. Corrected RSCN processing.
12. Correct link speed is negotiated when directly connected to a specific OEM array.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Driver Kit
Operating System
Linux - 2.6 Kernel
Version
8.0.16.40
Size Driver
227KB
File Name
lpfc_2.6_driver_kit-8.0.16.40-2.tar.gz
Observations
Support Resources for PRIMERGY Servers
RHEL4.7 and SLES9 SP4
Base driver and install script
1. System Requirements
1.1 Red Hat Enterprise Linux 'kernel-devel' Package Requirement
1.2 SuSE Linux Enterprise Server 'kernel-source' Package Requirement
2. Description of Install Procedure
3. Informational
3.1 Packaging Change Involving The Application Helper Module
3.1.1 Background
3.1.2 Observed Behavior
4. Known Issues
4.1 Uninstalling the Driver Kit on Boot-from-SAN Configurations
4.1.1 Observed problem
4.1.2 Resolution
4.2 Machine Check Exception
4.2.1 Observed problem
4.2.2 Workaround
4.3 Loading order of LPFC driver in initial ramdisk
4.3.1 Background
4.3.2 Observed Problem
4.3.3 Workaround
4.4 System panic while unloading the lpfc module
4.4.1 Background
4.4.2 Observed Problem
4.4.3 Resolution
4.5 PCI Hot Plug Support for applications
4.5.1 Observed problem
4.5.2 Workaround
4.6 Storage Array discovery issues in direct-attach configurations
4.6.1 Observed problem
4.6.2 Workaround
----------------------------------------------------------------------
1. System Requirements
The following distributions of Linux are supported by the Emulex
LPFC driver:
Red Hat Enterprise Linux 4 (Update 3 or higher)
SuSE Linux Enterprise Server 9 (SP2 or higher)
1.1 Red Hat Enterprise Linux 'kernel-devel' Package Requirement
For Red Hat Enterprise Linux installations, the kernel development
package with the same version as the currently running kernel must
be installed for the LPFC 8.0 driver build to succeed. For
example, a system with the 2.6.9-22.EL kernel would need the
kernel-devel-2.6.9-22.EL package, and a system with the
2.6.9-22.ELsmp kernel would need the kernel-smp-devel-2.6.9-22.EL
package.
1.2 SuSE Linux Enterprise Server 'kernel-source' Package Requirement
For SuSE Linux Enterprise Server installations, the kernel-source
package with the same version as the currently running kernel must
be installed for the LPFC 8.0 driver build to succeed. For
example, a system with the 2.6.5-7.139-bigsmp kernel would need the
kernel-source-2.6.5-7.139 package.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Driver Kit
Operating System
Linux - 2.6 Kernel
Version
8.2.0.22
Size Driver
274KB
File Name
lpfc_2.6_driver_kit-8.2.0.22-2.tar.gz
Observations
Support Resources for PRIMERGY Servers
RHEL5.2, SLES10 SP2
Base driver and install script (273 KB gz file)
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Driver Kit
Operating System
Linux - 2.6 Kernel
Version
8.2.0.33.3p
Size Driver
289KB
File Name
lpfc_2.6_driver_kit-8.2.0.33.3p-1.tar.gz
Observations
Red Hat Enterprise Linux 5.3, SUSE SLES 11 (x86 Intel,x86-64 AMD & Intel architectures)
Base driver and install script
1. System Requirements
1.1 Red Hat Enterprise Linux 'kernel-devel' Package Requirement
1.2 SuSE Linux Enterprise Server 'kernel-source' Package Requirement
2. Description of Install Procedure
3. Known Issues
3.1 PCI Hot Plug Support for applications
3.1.1 Observed problem
3.1.2 Workaround
3.2 Deletion of Vports/PCI Hot Unplug
3.2.1 Observed Problem
3.2.2 Background
3.3 lspci utility displays "Unknown Device" for LPe12000 HBAs
3.3.1 Observed Problem
3.3.2 Background
3.4 Speed of LPe12000 HBA (8Gb) is incorrectly displayed by HBAnyware
3.4.1 Observed Problem
3.4.2 Background
3.5 Port disabled on system boot or HBA reset with authentication enabled
3.5.1 Observed Problem
3.5.2 Workaround
3.6 LILO Boot Loader is not supported - i386 and x86_64 architectures
3.6.1 Observed Problem
3.6.2 Background
3.7 Order of lpfc module in initrd module list
3.7.1 Observed Problem
3.7.2 Workaround
3.8 Devloss timeout after swapping ports
3.8.1 Observed Problem
3.8.2 Workaround
3.9 Suspend to disk and Resume support
3.9.1 Observed Problem
3.9.2 Background
3.10 Deleting vports while devices are in use
3.10.1 Observed Problem
3.10.2 Workaround
----------------------------------------------------------------------
1. System Requirements
The following distributions of Linux are supported by the Emulex
LPFC driver:
Red Hat Enterprise Linux 5
SuSE Linux Enterprise Server 10 (SP1 or higher)
1.1 Red Hat Enterprise Linux 'kernel-devel' Package Requirement
For Red Hat Enterprise Linux installations, the -devel package
which matches the kernel package with the same version as the
currently running kernel must be installed for the LPFC driver
build to succeed. For example, a system with the 2.6.18-7 kernel
would need the kernel-devel-2.6.18-7 package.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Applications Kit
Operating System
Linux - 2.6 Kernel
Version
8.0.16.40
Size Driver
196.4MB
File Name
elxlinuxapps-3.4a14-8.0.16.40-2-1.tar
Observations
Support Resources for PRIMERGY Servers
RHEL4.7 and SLES9 SP4
HBAnyware utility 3.4a14, Application helper module 2.0.30
HBAnyware 3.4a14 Linux Installation Instructions
This installation kit contains the following components:
HBAnyware version 3.4a14
SSC version 3.4a14
DFC Library version 80.164-8
Lputil version
HBAAPI version 2.1.g
Dependencies:
lpfc driver version 8.0.16.40 or later
HBAnyware requires that the lpfc driver module be installed.
HBAnyware requires a minimum screen resolution of 1024 x 768.
Installing HBAnyware:
1. Copy the applications kit tar file to a directory on the install machine
2. cd to the directory which you copied the tar file
3. Untar the file: tar -xvf tarfilename
4. cd (change directory) to the "ElxLinuxApps.." directory created by step 3
5. su to root
6. If earlier HBAnyware version currently installed, type : ./uninstall
7. Run the install script: ./install
8. When prompted, answer the following question:
Select desired mode of operation for HBAnyware
1 Local Mode : HBA's on this Platform can be managed by HBAnyware
clients on this platform only.
2 Managed Mode : HBA's on this Platform can be managed by local or
remote HBAnyware clients
3 Remote Mode : Same as '2' plus HBAnyware clients on this Platform
can manage local and remote clients.
Enter the number '1' or '2' or '3'
9. When prompted, answer the following question:
Do you want to allow user to make subsequent management mode changes
using 'set_operating_mode' script
Enter the letter 'Y' for yes or 'N' for no
10. Installation Complete: type /usr/sbin/hbanyware/hbanyware
to start GUI or type /usr/sbin/hbanyware/hbacmd list
to run script utility
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Applications Kit
Operating System
Linux - 2.6 Kernel
Version
8.2.0.22
Size Driver
198.5MB
File Name
elxlinuxapps-3.4a14-8.2.0.22-2-2.tar
Observations
Red Hat Enterprise Linux 5.2 and SUSE SLES 10 SP2 (Intel x86, Intel Itanium2, Intel EM64T, AMD64, and PowerPC 64-bit architectures)
HBAnyware utility 3.4a14 (198 MB tar file)
HBAnyware 3.4a14 Linux Installation Instructions
This installation kit contains the following components:
HBAnyware version 3.4a14
SSC version 3.4a14
DFC Library version 3.0.13-1
Lputil version
HBAAPI version 2.1.g
Dependencies:
lpfc driver version 8.2.0.22 or later
HBAnyware requires that the lpfc driver module be installed.
HBAnyware requires a minimum screen resolution of 1024 x 768.
Installing HBAnyware:
1. Copy the applications kit tar file to a directory on the install machine
2. cd to the directory which you copied the tar file
3. Untar the file: tar -xvf tarfilename
4. cd (change directory) to the "ElxLinuxApps.." directory created by step 3
5. su to root
6. If earlier HBAnyware version currently installed, type : ./uninstall
7. Run the install script: ./install
8. When prompted, answer the following question:
Select desired mode of operation for HBAnyware
1 Local Mode : HBA's on this Platform can be managed by HBAnyware
clients on this platform only.
2 Managed Mode : HBA's on this Platform can be managed by local or
remote HBAnyware clients
3 Remote Mode : Same as '2' plus HBAnyware clients on this Platform
can manage local and remote clients.
Enter the number '1' or '2' or '3'
9. When prompted, answer the following question:
Do you want to allow user to make subsequent management mode changes
using 'set_operating_mode' script
Enter the letter 'Y' for yes or 'N' for no
10. Installation Complete: type /usr/sbin/hbanyware/hbanyware
to start GUI or type /usr/sbin/hbanyware/hbacmd list
to run script utility
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Applications Kit
Operating System
Linux - 2.6 Kernel
Version
8.2.0.33.3p
Size Driver
201.4MB
File Name
elxlinuxapps-4.0a31-8.2.0.33.3p-1-3.tar
Observations
Support Resources for PRIMERGY Servers
RHEL5.3
HBAnyware utility 4.0a31
HBAnyware 4.0a31 Linux Installation Instructions
This installation kit contains the following components:
HBAnyware version 4.0a31
SSC version 4.0a31
DFC Library version 3.0.28-1-1
HBAAPI version 2.1.g
Multipulse version 3.0.30-1
FCAUTHD version 1.19-1-1
Dependencies:
lpfc driver version 8.2.0.33.3p or later
HBAnyware requires that the lpfc driver module be installed.
HBAnyware requires a minimum screen resolution of 1024 x 768.
Installing HBAnyware:
1. Copy the applications kit tar file to a directory on the install machine
2. cd to the directory which you copied the tar file
3. Untar the file: tar -xvf tarfilename
4. cd (change directory) to the "ElxLinuxApps.." directory created by step 3
5. su to root
6. If earlier HBAnyware version currently installed, type : ./uninstall
7. Run the install script: ./install
8. When prompted, answer the following question:
Select desired mode of operation for HBAnyware
1 Local Mode : HBA's on this Platform can be managed by HBAnyware
clients on this platform only.
2 Managed Mode : HBA's on this Platform can be managed by local or
remote HBAnyware clients
3 Remote Mode : Same as '2' plus HBAnyware clients on this Platform
can manage local and remote clients.
Enter the number '1' or '2' or '3'
9. When prompted, answer the following question:
Do you want to allow user to make subsequent management mode changes
using 'set_operating_mode' script
Enter the letter 'Y' for yes or 'N' for no
10. Installation Complete: type /usr/sbin/hbanyware/hbanyware
to start GUI or type /usr/sbin/hbanyware/hbacmd list
to run script utility
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Storport Miniport Driver User Manual
Information
Windows 2003-2008
Operating System
Manual
Version
2.20.006
Size Driver
1.2MB
File Name
manual.pdf
Observations
Qualification: Microsoft currently does not offer an FCoE WHQL "Certified for Windows" logo program. When the Storport Miniport driver is used with a standard Fibre Channel HBA, the driver is qualified for the "Certified for Windows" logo program. When the Storport MiniPort driver is used with an FCoE CNA, the driver is considered "unclassified" by Microsoft. In both cases, the Storport Miniport drivers are digitally signed by Microsoft and will be recognized by Windows Sever 2003, Windows Server 2008 and Windows Server 2008 R2.
Note For Windows Server 2003, SP2 and the KB932755 update to the Microsoft Storport driver are required. KB945119 is recommended. The Storport KB update must be applied before the Emulex Storport Miniport driver can be installed.
Tested Architectures: x86, x64, IA64
Storport Miniport Driver Version 2.20 for Windows Server 2003 and Windows Server 2008
Installation ...............................................................................................1
Driver Information .................................................................................................... 1
Supported Features........................................................................................... 1
New Features in this Release............................................................................ 1
Prerequisites ..................................................................................................... 2
For the lpfc Driver Kit .................................................................................. 2
Compatibility...................................................................................................... 2
Things to Know Before You Download .............................................................. 3
Known Issues .................................................................................................... 3
Installing the Driver Kit ............................................................................................ 3
Driver Kit Install Script Options.......................................................................... 4
Driver Kit Directory Structure ............................................................................. 4
Installing the Driver on Unsupported Linux Distributions.......................................... 5
Upgrading the Kernel or Applying a Distribution Service Pack or Update ................ 5
Installing the Driver Kit into an Upgraded Kernel ............................................... 5
Booting From a Non-Zero LUN Attached to an Emulex Adapter .............................. 6
Installing the HBAnyware Utility ............................................................................... 6
Uninstalling the Driver Kit .................................................................................. 7
Configuration ..........................................................................................8
Driver Configuration Methods Using modprobe and
/etc/modprobe.conf............................................................................................ 8
Temporary Configuration Method ................................................................ 8
Persistent Configuration Method ................................................................. 8
Temporary Driver Configuration by Read/Write to sysfs .................................... 9
Creating a New Ramdisk Image ...................................................................... 10
For Installed lpfc Driver Kits ...................................................................... 10
For Distribution In-Box lpfc Drivers............................................................ 10
Dynamically Adding LUNs and Targets............................................................ 10
Driver Parameters Reference Table ................................................................ 11
Using udev for Persistent Naming ................................................................... 15
Using udev to Discover Logical to Physical Mappings for sd Devices ....... 15
Configuring the System to Boot From SAN Using Persistent Names ........ 15
Using udev with st Devices ....................................................................... 16
Further Information About Persistent Names ............................................ 17
Working with Virtual Ports (vports)......................................................................... 18
Creating, Deleting and Displaying vports......................................................... 18
The mkvport.sh Script ............................................................................... 18
The rmvport.sh Script................................................................................ 19
The lsvport.sh Script ................................................................................. 19
The vport Sysfs Tree ....................................................................................... 19
Driver Version 8.2.8.14 sysfs Structure............................................................ 20
Vport sysfs Entries .................................................................................... 21
Vport Configuration Limits ............................................................................... 23
DHCHAP Authentication and Configuration ........................................................... 24
Authentication Configuration Parameters ........................................................ 25
Setting Remote and Local Passwords ............................................................. 25
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Quick Installation Manual
Information
Windows 2003-2008
Operating System
Manual
Version
2.20.006
Size Driver
256KB
File Name
quick_installation.pdf
Observations
Qualification: Microsoft currently does not offer an FCoE WHQL "Certified for Windows" logo program. When the Storport Miniport driver is used with a standard Fibre Channel HBA, the driver is qualified for the "Certified for Windows" logo program. When the Storport MiniPort driver is used with an FCoE CNA, the driver is considered "unclassified" by Microsoft. In both cases, the Storport Miniport drivers are digitally signed by Microsoft and will be recognized by both Windows Sever 2003 and Windows Server 2008.
Note For Windows Server 2003, SP2 and the KB932755 update to the Microsoft Storport driver are required. KB945119 is recommended. The Storport KB update must be applied before the Emulex Storport Miniport driver can be installed.
AutoPilot Installer for Windows Server 2003 and Windows Server 2008
Introduction
AutoPilot Installer® for Emulex® drivers provides installation options that range from a simple installation
with a few mouse clicks to custom unattended installations using predefined script files.
AutoPilot Installer is included with Emulex drivers and utilities in Windows executable files that can be
downloaded from the Emulex Web site. Run the distribution executable file to extract all of the software
needed for an installation, then complete the installation using AutoPilot Installer.
AutoPilot Installer allows you to install a driver using any of the following methods:
Hardware-first installation. The host bus adapter (HBA) is installed before the downloaded Emulex
drivers and utilities are installed. See page 3 for this procedure.
Software-first installation. This new installation method allows drivers and utilities to be downloaded
from the Emulex Web site and installed using AutoPilot Installer prior to the installation of any HBAs. The
drivers and utilities are automatically used when HBAs are installed at a later time. See page 4 for this
procedure.
Unattended installation. This new installation method allows you to set up AutoPilot Installer to run
unattended using customized scripts. Unattended installation can be used for both hardware-first and
software-first installations. See the complete Installation section of the driver user manual for more
information.
Note: Complete driver and utilities documentation may be downloaded from the Emulex Web site
(www.emulex.com). Click Support at the top of the Web page and navigate by clicking the appropriate
links.
Updating the Driver Using AutoPilot Installer
If you are currently running an older driver version, use the hardware-first installation procedure to
update your driver. Begin at step 2 to update the driver.
You can also update the Emulex drivers following the manual installation method. See the complete
Installation section of the driver user manual for this procedure.
Distribution Executable File Overview
The distribution executable file is a self-extracting file that includes the following:
• AutoPilot Installer - installs driver and utilities.
• Driver - manages communication and data transfer between applications and I/O devices, using
HBAs as agents.
• HBAnyware utility - performs installation and configuration tasks on remote and local adapters.
Distribution Executable File Procedure
To run the distribution executable file:
1. Download the distribution executable file from the Emulex Web site to your system.
2. Double-click the distribution executable file. A window is displayed with driver version
information and Emulex contact information
3. Click Next to access the Location window or click Cancel to close the window.
4. The default installation location is displayed. Browse to a different location, if desired. Click
Install to continue the installation.
5. The Progress window is displayed. As each task is completed, the corresponding checkbox is
automatically selected.
6. After all tasks are completed, a confirmation window is displayed. The Start AutoPilot Installer
checkbox is automatically selected. To start AutoPilot Installer later, clear this checkbox.
7. Click Finish to close the distribution executable file.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Manual
Information
Boot Code
Operating System
Manual
Size Driver
4.9MB
File Name
bootcode.pdf
Observations
Support Resources for PRIMERGY Servers
Platform: Intel (32-bit) Introduction..............................................................................................................1
Emulex Boot Code Files....................................................................................1
Boot from SAN.........................................................................................................2
Windows Server 2008 and Windows Server 2003.............................................2
Configure Boot from SAN on Windows Server 2008 and Windows Server 2003 (x86 and x64)..........................................................2
Configure Boot from SAN on Windows Server 2008 and Windows Server 2003 (Itanium)..................................................................3
New Installation of Windows 2008 UEFI- Aware Operating System
on a UEFI-based x64 Server.................................................................3
Direct a UEFI-Based Server to a Windows Server 2008 OS Image (Installed as UEFI-Aware) Already Installed on the SAN.......................4
The GUID Partition Table......................................................................4
Install Windows Server 2008 on an FC Boot Disk (x86, x64 and Itanium)...5
Install Windows Server 2003 on an FC Boot Disk (x86, and x64
and Itanium)................................................................................................6
Linux and VMware.............................................................................................7
Configure Boot from SAN on Linux or VMware (x86 and x64).....................7
Configure Boot from SAN on Linux (PowerPC)...........................................7
Configure Boot from SAN on Linux (Itanium)..............................................7
Solaris...............................................................................................................8
Configure Boot from SAN on Solaris SFS (x86 and x64)............................8
Determine LUNs to Select for Boot from SAN.......................................8
Configure Boot from SAN on Solaris SFS (SPARC)....................................8
Configure Boot from SAN on Solaris LPFC (SPARC)..................................9
Install Solaris from a Network Image..................................................10
Install Solaris by Migrating an Image from a Local SCSI Disk.............11
Install, Update and Enable Boot Code...................................................................14
BIOS Utility............................................................................................................15
Start the BIOS Utility.................................................................................15
Enable an Adapter to Boot from SAN........................................................17
Configure Boot Devices...................................................................................17
Configure Adapter Parameters........................................................................21
Change the Default AL_PA (Arbitrated Loop Physical Address)................22
Change the PLOGI Retry Timer................................................................23
Change Topology......................................................................................24
Enable or Disable the Spinup Delay..........................................................25
Set Auto Scan...........................................................................................26
Enable or Disable EDD 3.0.......................................................................27
Enable or Disable the Start Unit Command...............................................28
Enable or Disable the Environment Variable.............................................29
Enable or Disable Auto Boot Sector..........................................................30
Change Link Speed...................................................................................31
Reset to Default Values.............................................................................32
Use Multi-Path Boot from SAN..................................................................33
OpenBoot..............................................................................................................34
Attribute Commands.................................................................................34
Functional Commands..............................................................................35
EFIBoot.................................................................................................................37
Install the EFI Utility..................................................................................37
Start the EFI Utility....................................................................................38
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Linux User Manual
Information
Linux - 2.6 Kernel
Operating System
Manual
Version
8.2.0.22
Size Driver
1.5MB
File Name
manual.pdf
Observations
Support Resources for PRIMERGY Servers
RHEL5.2, SLES10 SP2
Driver for Linux User Manual
Installation ...............................................................................................1
Driver Information .................................................................................................... 1
Supported Features........................................................................................... 1
New Features in this Release............................................................................ 1
Prerequisites ..................................................................................................... 2
For the lpfc Driver Kit .................................................................................. 2
Compatibility...................................................................................................... 2
Things to Know Before You Download .............................................................. 3
Known Issues .................................................................................................... 3
Installing the Driver Kit ............................................................................................ 3
Driver Kit Install Script Options.......................................................................... 4
Driver Kit Directory Structure ............................................................................. 4
Installing the Driver on Unsupported Linux Distributions.......................................... 5
Upgrading the Kernel or Applying a Distribution Service Pack or Update ................ 5
Installing the Driver Kit into an Upgraded Kernel ............................................... 5
Booting From a Non-Zero LUN Attached to an Emulex Adapter .............................. 6
Installing the HBAnyware Utility ............................................................................... 6
Uninstalling the Driver Kit .................................................................................. 7
Configuration ..........................................................................................8
Driver Configuration Methods Using modprobe and
/etc/modprobe.conf............................................................................................ 8
Temporary Configuration Method ................................................................ 8
Persistent Configuration Method ................................................................. 8
Temporary Driver Configuration by Read/Write to sysfs .................................... 9
Creating a New Ramdisk Image ...................................................................... 10
For Installed lpfc Driver Kits ...................................................................... 10
For Distribution In-Box lpfc Drivers............................................................ 10
Dynamically Adding LUNs and Targets............................................................ 10
Driver Parameters Reference Table ................................................................ 11
Using udev for Persistent Naming ................................................................... 15
Using udev to Discover Logical to Physical Mappings for sd Devices ....... 15
Configuring the System to Boot From SAN Using Persistent Names ........ 15
Using udev with st Devices ....................................................................... 16
Further Information About Persistent Names ............................................ 17
Working with Virtual Ports (vports)......................................................................... 18
Creating, Deleting and Displaying vports......................................................... 18
The mkvport.sh Script ............................................................................... 18
The rmvport.sh Script................................................................................ 19
The lsvport.sh Script ................................................................................. 19
The vport Sysfs Tree ....................................................................................... 19
Driver Version 8.2.8.14 sysfs Structure............................................................ 20
Vport sysfs Entries .................................................................................... 21
Vport Configuration Limits ............................................................................... 23
DHCHAP Authentication and Configuration ........................................................... 24
Authentication Configuration Parameters ........................................................ 25
Setting Remote and Local Passwords ............................................................. 25
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Installation Manual
Information
Hardware Manuals
Operating System
Manual
Size Driver
296KB
File Name
lpe1150.pdf
Observations
Support Resources for PRIMERGY Servers Introduction..................................................................................................................................................1
Major Features...............................................................................................................................1
Compatibility...................................................................................................................................2
Prerequisites...................................................................................................................................2
Installing the Host Bus Adapter....................................................................................................................2
Attaching Media...........................................................................................................................................4
Applying Power............................................................................................................................................5
Viewing the LEDs...........................................................................................................................5
POST Conditions and Results.........................................................................................................5
References..................................................................................................................................................7
Specifications.................................................................................................................................7
FCC and Regulatory Notices...........................................................................................................8
Declaration of Conformity................................................................................................................9
Laser Safety Notice.......................................................................................................................11
Introduction
The Emulex® LPe1150 host bus adapter (HBA) is a single-channel, 4.25 gigabit per second (Gb/s), Fibre
Channel (FC) Peripheral Component Interconnect Express (PCIe) HBA. The core technology of this
HBA is Emulex’s eighth generation FC controller. The controller incorporates a multifunction native PCIe
core that is compliant to the PCIe Base Specification 1.0a and PCI Express CEM Specification 1.0a. The
HBA supports packet transfers up to 2048 bytes on the PCIe link with support for x1 or x4 lane
negotiation. The supported physical PCIe connector is x4 or higher (x8 or x16). The fully featured FC
port is compliant to various American National Standards Institute (ANSI) FC standards. The product is
targeted at FC storage networking environments that require the highest degrees of robustness,
performance and ease of management.
Major Features
• PCIe device with with one FC port
• Auto-negotiation between 1-Gb, 2-Gb or 4-Gb link attachments
• High performance FC HBA with the PCIe to FC controller with one internal processor
• Full support for all FC topologies including point-to-point, arbitrated loop and fabric
• Full support for FC service class 2 and 3
• Maximum FC throughput achieved via full duplex hardware support
• End-to-end data path-parity and cyclical redundancy check (CRC) protection, including internal
data path random-access memory (RAM)
• Architectural support for multiple upper layer protocols
• State-of-the-art circuitry:
•All PCIe and FC functionality contained within a single, custom, high-density, fully integrated FC controller
•Internal ARM 1136J-S processor with instruction and data cache for each port
•Internal serializer deserializer (SerDes) 1-Gb/2-Gb/4-Gb core for FC and 2.5-Gb cores for PCIe
• Complies with the PCIe base and CEM 1.0a specifications:
•x1 or x4 lane link interface (auto-negotiated with system) at 2.5-Gb/s
•Supports VC0 (1 Virtual Channel) and TC0 (1 Traffic Class)
•Configuration /IO/ Memory read/write, completion and message
•Supports 64-bit addressing
•ECRC for all transmitted PCIe data packets
•Link CRC on all PCIe packets and message information
•Supports large payload size- 2048 bytes for read/write
•Supports large read request size- 4096 bytes
• Internal high-speed static RAM (SRAM)
• Error correcting code (ECC) protection of local memory, including single-bit correction and
double-bit protection
• The LPe1150 HBA provides an embedded short wave optical (LC) connection with link
diagnostics capability.
• Host interface via Emulex standard drivers or through custom drivers written to the Emulex
Service Level Interface (SLI-2) that is compatible with the many existing Emulex drivers for
products such as LP8000, LP9002L, LP9802, LP10000 HBAs
• Comprehensive array of operating system (OS) drivers:
•Emulex standard device drivers for Windows 2000 Server, Windows Server 2003, Novell NetWare and Linux
•Some drivers support both SCSI and IP protocols
•Support for remote and fabric boot functionality
• On-board context management by the firmware:
•Up to 510 FC port logins
•Up to 1023 concurrent exchanges
•I/O multiplexing down to the FC frame level
• Data buffers capable of supporting 16 buffer-to-buffer (BB) credits for short-wave applications
• Link management and recovery handled by the firmware
• On-board diagnostic capability accessible via optional connection
• Parts and construction compliant to the European Union Directive of Restriction of Hazardous
Substances (RoHS)
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Driver Manual
Information
Linux - 2.6 Kernel
Operating System
Manual
Version
8.0.16.40
Size Driver
1.1MB
File Name
manual.pdf
Observations
Support Resources for PRIMERGY Servers
RHEL4.7 and SLES9 SP4
Driver for Linux User Manual
Installation ...............................................................................................1
Driver Information .................................................................................................... 1
Supported Features........................................................................................... 1
New Features in this Release............................................................................ 1
Prerequisites ..................................................................................................... 2
For the lpfc Driver Kit .................................................................................. 2
Compatibility...................................................................................................... 2
Things to Know Before You Download .............................................................. 3
Known Issues .................................................................................................... 3
Installing the Driver Kit ............................................................................................ 3
Driver Kit Install Script Options.......................................................................... 4
Driver Kit Directory Structure ............................................................................. 4
Installing the Driver on Unsupported Linux Distributions.......................................... 5
Upgrading the Kernel or Applying a Distribution Service Pack or Update ................ 5
Installing the Driver Kit into an Upgraded Kernel ............................................... 5
Booting From a Non-Zero LUN Attached to an Emulex Adapter .............................. 6
Installing the HBAnyware Utility ............................................................................... 6
Uninstalling the Driver Kit .................................................................................. 7
Configuration ..........................................................................................8
Driver Configuration Methods Using modprobe and
/etc/modprobe.conf............................................................................................ 8
Temporary Configuration Method ................................................................ 8
Persistent Configuration Method ................................................................. 8
Temporary Driver Configuration by Read/Write to sysfs .................................... 9
Creating a New Ramdisk Image ...................................................................... 10
For Installed lpfc Driver Kits ...................................................................... 10
For Distribution In-Box lpfc Drivers............................................................ 10
Dynamically Adding LUNs and Targets............................................................ 10
Driver Parameters Reference Table ................................................................ 11
Using udev for Persistent Naming ................................................................... 15
Using udev to Discover Logical to Physical Mappings for sd Devices ....... 15
Configuring the System to Boot From SAN Using Persistent Names ........ 15
Using udev with st Devices ....................................................................... 16
Further Information About Persistent Names ............................................ 17
Working with Virtual Ports (vports)......................................................................... 18
Creating, Deleting and Displaying vports......................................................... 18
The mkvport.sh Script ............................................................................... 18
The rmvport.sh Script................................................................................ 19
The lsvport.sh Script ................................................................................. 19
The vport Sysfs Tree ....................................................................................... 19
Driver Version 8.2.8.14 sysfs Structure............................................................ 20
Vport sysfs Entries .................................................................................... 21
Vport Configuration Limits ............................................................................... 23
DHCHAP Authentication and Configuration ........................................................... 24
Authentication Configuration Parameters ........................................................ 25
Setting Remote and Local Passwords ............................................................. 25
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Basic Troubleshooting Manual
Information
Hardware Manuals
Operating System
Manual
Size Driver
157KB
File Name
troubleshooting_basic.pdf
Observations
Support Resources for PRIMERGY Servers Emulex Product Installation, Upgrades, and Configuration
Installing, upgrading and configuring Emulex products can be easily accomplished by following the checklists provided at the end of this document.
A word about Emulex configuration parameters:
Emulex drivers and software provide a great degree of configurability. In particular, each driver has a number of configuration parameters that allow the customization of the behavior of the driver. Because these parameters can significantly change the behavior of the Emulex product, great care must be taken in the setting of the parameters. Storage and system providers put forth great effort in determining what particular configuration parameters must be set to in order to provide optimal SAN performance.
For best results, never change the driver configuration parameters from their default values or the values that are specified by the storage and systems providers. Doing so can alter to performance of the SAN and possibly place the SAN in a configuration that is not supported or cause it not to operate properly.
How Emulex device driver configuration parameters work
It is very important to understand that Emulex configuration parameters are stored in the server in which the HBA is installed into. The parameters are acted upon by the device driver. Emulex configuration parameters are NOT stored in the HBA flash memory. Unlike some other SCSI and Fibre Channel HBAs, Emulex does not store any configuration information such as timers, Fibre Channel topology or link speed in the HBA flash. When an Emulex HBA is installed into a server, there is no separate configuration step required for the HBA. Proper driver configuration is all that is required. The exception is booting from SAN. In this case, the HBA BIOS utility must be used to configure the boot device. Said differently, the HBA must be told which Fibre Channel device contains the boot volume, and that information is stored in the flash. These settings are only in effect at boot time. Once the operating system loads the device driver, most settings of the driver are used and the HBA BIOS no longer functions.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Advanced Troubleshooting Manual
Information
Hardware Manuals
Operating System
Manual
Size Driver
649KB
File Name
troubleshooting.pdf
Observations
Overview................................................................................................................ 1
Be Informed, Stay Informed, Stay Current 1
The Importance of Compatibility, Driver Updates and Firmware Updates 1
Driver Updates........................................................................................... 1
Firmware Updates...................................................................................... 2
Emulex Configuration Parameters 3
How Emulex Device Driver Configuration Parameters Work...................... 3
Emulex Applications 3
Troubleshooting...................................................................................................... 4
Observing the Problem 4
Isolating the Problem 4
SAN Components...................................................................................... 4
Server Components................................................................................... 5
Checklists 6
Connectivity Checklist................................................................................ 6
Installation Checklist.................................................................................. 7
Upgrade Checklist...................................................................................... 8
Configuration Checklist.............................................................................. 8
Tools to Collect Data 9
Driver Tools - Event Logging...................................................................... 9
The OneCommand Manager and HBAnyware Applications....................... 9
Other Ways to Collect Data...................................................................... 10
Common Problems 10
Hardware Issues...................................................................................... 10
Link Down................................................................................................ 10
Cannot See Devices or Drives................................................................. 11
Out-of-Date Driver Version....................................................................... 12
Out-of-Date Firmware Version.................................................................. 12
OneConnect and LightPulse LP21000 Adapters 13
OneConnect and LP21000 Checklist....................................................... 13
OneConnect and LP21000 Symptoms..................................................... 13
When to Contact Emulex...................................................................................... 14
Emulex Web Site and Emulex Support................................................................. 15
Emulex Support Page 15
Contact Emulex After Hours, Weekends or Holidays............................... 17
LED Reference Information.................................................................................. 18
Firmware Operation and Port Activity LEDs 18
Common LED States 18
Normal Link Up........................................................................................ 18
Link-Down or adapter waiting................................................................... 19
Heart-beat indication................................................................................ 19
OneConnect CNA LEDs........................................................................... 19
LP21000 LEDs......................................................................................... 19
LED Table................................................................................................ 21
Driver Updates
To update your driver, download the latest Emulex driver and utilities from the Emulex Web site. From
the main Emulex Web site, click Downloads, click your vendor and then click the link for your operating
system (OS).
Drivers for Windows
• The drivers for Windows include support for Windows Server 2008 R2, Windows Server 2008,
Windows Server 2003, Windows 2000 Server and Windows NT (No future versions of drivers for
Windows 2000 Server or Windows NT are planned.)
•The driver kit download includes the base driver and the OneCommand Manager application.
•If you are running Windows Server 2008 R2, Windows Server 2008, Windows Server 2003 or Windows 2000 Server, the driver kit download includes AutoPilot Installer®, which enables you to quickly install or update drivers and utilities and configure adapters, drivers and utilities.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
HBAnyware User Manual
Information
Windows 2003-2008
Operating System
Manual
Version
2.20.006
Size Driver
4.6MB
File Name
hbanyware.pdf
Observations
Qualification: Microsoft currently does not offer an FCoE WHQL "Certified for Windows" logo program. When the Storport Miniport driver is used with a standard Fibre Channel HBA, the driver is qualified for the "Certified for Windows" logo program. When the Storport MiniPort driver is used with an FCoE CNA, the driver is considered "unclassified" by Microsoft. In both cases, the Storport Miniport drivers are digitally signed by Microsoft and will be recognized by Windows Sever 2003, Windows Server 2008 and Windows Server 2008 R2.
Note For Windows Server 2003, SP2 and the KB932755 update to the Microsoft Storport driver are required. KB945119 is recommended. The Storport KB update must be applied before the Emulex Storport Miniport driver can be installed.
Tested Architectures: x86, x64, IA64
HBAnyware Utility Version 4.1
Introduction.............................................................................................................. 1
Known Issues .................................................................................................... 1
Installing HBAnyware Components.......................................................................... 2
Installing the HBAnyware Utility......................................................................... 2
Installing the HBAnyware Utility with Web Launch............................................. 4
Installing the HBAnyware Utility Security Configurator ...................................... 5
Uninstalling the HBAnyware Security Configurator............................................ 6
Uninstalling HBAnyware Web Launch Only ....................................................... 7
Uninstalling the Utility Package ......................................................................... 7
Using the HBAnyware Components......................................................................... 8
Starting the HBAnyware Utility........................................................................... 8
Starting HBAnyware with Web Launch .............................................................. 8
Starting the HBAnyware Security Configurator .................................................. 8
Starting HBAnyware from the Command Line ................................................... 9
Examples of Modifications .................................................................... 9
The HBAnyware Utility Window Element Definitions ....................................... 10
The Menu Bar ........................................................................................... 11
The Toolbar ............................................................................................... 11
The Toolbar Buttons .................................................................................. 11
Sort Toolbar Buttons ........................................................................... 11
The Discovery-Tree................................................................................... 12
Discovery-Tree Icons .......................................................................... 12
Property Tabs............................................................................................ 13
Status Bar ................................................................................................. 13
Changing Management Mode ......................................................................... 13
Resetting HBAs ............................................................................................... 14
Discovering HBAs ........................................................................................... 14
Automatic Fibre Channel Discovery .......................................................... 14
Remote SAN Management Using TCP/IP Access Protocol....................... 15
Adding a Single Host .......................................................................... 15
Adding a Range of Hosts .................................................................... 16
Removing Hosts.................................................................................. 17
Configuring Discovery Settings ................................................................. 18
Sorting HBA Information.................................................................................. 19
Viewing Remote and Local HBAs.............................................................. 19
Viewing HBA Information................................................................................. 20
Viewing Discovery Information .................................................................. 20
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
HBAnyware User Manual
Information
Linux - 2.6 Kernel
Operating System
Manual
Version
8.2.0.33.3p
Size Driver
5.3MB
File Name
hbanyware.pdf
Observations
Support Resources for PRIMERGY Servers
RHEL5.3
HBAnyware Utility Version 4.0 Introduction.............................................................................................................. 1
Known Issues .................................................................................................... 1
Installing HBAnyware Components.......................................................................... 2
Installing the HBAnyware Utility......................................................................... 2
Installing the HBAnyware Utility with Web Launch............................................. 4
Installing the HBAnyware Utility Security Configurator ...................................... 5
Uninstalling the HBAnyware Security Configurator............................................ 6
Uninstalling HBAnyware Web Launch Only ....................................................... 7
Uninstalling the Utility Package ......................................................................... 7
Using the HBAnyware Components......................................................................... 8
Starting the HBAnyware Utility........................................................................... 8
Starting HBAnyware with Web Launch .............................................................. 8
Starting the HBAnyware Security Configurator .................................................. 8
Starting HBAnyware from the Command Line ................................................... 9
Examples of Modifications .................................................................... 9
The HBAnyware Utility Window Element Definitions ....................................... 10
The Menu Bar ........................................................................................... 11
The Toolbar ............................................................................................... 11
The Toolbar Buttons .................................................................................. 11
Sort Toolbar Buttons ........................................................................... 11
The Discovery-Tree................................................................................... 12
Discovery-Tree Icons .......................................................................... 12
Property Tabs............................................................................................ 13
Status Bar ................................................................................................. 13
Changing Management Mode ......................................................................... 13
Resetting HBAs ............................................................................................... 14
Discovering HBAs ........................................................................................... 14
Automatic Fibre Channel Discovery .......................................................... 14
Remote SAN Management Using TCP/IP Access Protocol....................... 15
Adding a Single Host .......................................................................... 15
Adding a Range of Hosts .................................................................... 16
Removing Hosts.................................................................................. 17
Configuring Discovery Settings ................................................................. 18
Sorting HBA Information.................................................................................. 19
Viewing Remote and Local HBAs.............................................................. 19
Viewing HBA Information................................................................................. 20
Viewing Discovery Information .................................................................. 20
Viewing Host Information .......................................................................... 21
The Host Information Tab.................................................................... 21
The Driver Parameters Tab................................................................. 22
Viewing General HBA Attributes ............................................................... 23
Viewing Detailed HBA Information ............................................................ 24
Viewing Fabric Information........................................................................ 26
Viewing Target Information........................................................................ 27
Viewing LUN Information........................................................................... 28
Masking and Unmasking LUNs (Windows, Solaris LPFC and
Solaris SFS)........................................................................................ 29
Viewing Port Statistics............................................................................... 31
Viewing Firmware Information ................................................................... 33
Viewing Target Mapping (Windows, Solaris LPFC and Solaris SFS)......... 34
Viewing Target Mapping (Linux) ................................................................ 35
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
HBAnyware User Manual
Information
Linux - 2.6 Kernel
Operating System
Manual
Version
8.0.16.40
Size Driver
3.5MB
File Name
hbanyware.pdf
Observations
Support Resources for PRIMERGY Servers
RHEL4.7 and SLES9 SP4
HBAnyware Utility User Manual
Introduction.............................................................................................................. 1
Known Issues .................................................................................................... 1
Installing HBAnyware Components.......................................................................... 2
Installing the HBAnyware Utility......................................................................... 2
Installing the HBAnyware Utility with Web Launch............................................. 4
Installing the HBAnyware Utility Security Configurator ...................................... 5
Uninstalling the HBAnyware Security Configurator............................................ 6
Uninstalling HBAnyware Web Launch Only ....................................................... 7
Uninstalling the Utility Package ......................................................................... 7
Using the HBAnyware Components......................................................................... 8
Starting the HBAnyware Utility........................................................................... 8
Starting HBAnyware with Web Launch .............................................................. 8
Starting the HBAnyware Security Configurator .................................................. 8
Starting HBAnyware from the Command Line ................................................... 9
Examples of Modifications .................................................................... 9
The HBAnyware Utility Window Element Definitions ....................................... 10
The Menu Bar ........................................................................................... 11
The Toolbar ............................................................................................... 11
The Toolbar Buttons .................................................................................. 11
Sort Toolbar Buttons ........................................................................... 11
The Discovery-Tree................................................................................... 12
Discovery-Tree Icons .......................................................................... 12
Property Tabs............................................................................................ 13
Status Bar ................................................................................................. 13
Changing Management Mode ......................................................................... 13
Resetting HBAs ............................................................................................... 14
Discovering HBAs ........................................................................................... 14
Automatic Fibre Channel Discovery .......................................................... 14
Remote SAN Management Using TCP/IP Access Protocol....................... 15
Adding a Single Host .......................................................................... 15
Adding a Range of Hosts .................................................................... 16
Removing Hosts.................................................................................. 17
Configuring Discovery Settings ................................................................. 18
Sorting HBA Information.................................................................................. 19
Viewing Remote and Local HBAs.............................................................. 19
Viewing HBA Information................................................................................. 20
Viewing Discovery Information .................................................................. 20
Viewing Host Information .......................................................................... 21
The Host Information Tab.................................................................... 21
The Driver Parameters Tab................................................................. 22
Viewing General HBA Attributes ............................................................... 23
Viewing Detailed HBA Information ............................................................ 24
Viewing Fabric Information........................................................................ 26
Viewing Target Information........................................................................ 27
Viewing LUN Information........................................................................... 28
Masking and Unmasking LUNs (Windows, Solaris LPFC and
Solaris SFS)........................................................................................ 29
Viewing Port Statistics............................................................................... 31
Viewing Firmware Information ................................................................... 33
Viewing Target Mapping (Windows, Solaris LPFC and Solaris SFS)......... 34
Viewing Target Mapping (Linux) ................................................................ 35
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Firmware Update Manual
Information
Firmware
Operating System
Manual
Size Driver
106KB
File Name
fwupdate.pdf
Observations
Support Resources for PRIMERGY Servers Introduction.............................................................................................................. 1
Prerequisites ..................................................................................................... 1
Things to Know Before You Download ............................................................. 1
Update Utilities ........................................................................................................ 2
Introduction
For information about any firmware release, see the release notes on the Emulex Web site. Release
notes include information such as new features, compatibility, known issues and resolved known issues.
This manual does not contain the procedures themselves. It serves as a guide to the publication that
contains the procedures you need.
Prerequisites
• Local boot disk.
• The intended Fibre Channel target should be big enough to hold all system files and the swap
slice of the current local boot disk.
Things to Know Before You Download
• Before you download the OneConnect or LightPulse files, create a directory for them.
• As a measure of protection, ensure that critical files on your local boot disk are backed up.
• Firmware may be bundled with boot code. Boot code allows you to designate a device that is
attached to the adapter as a boot drive. If you select a firmware image that includes boot code,
the update procedure will load both the new firmware and the boot code at the same time. After
updating, refer to the Emulex Boot Manual for procedures on enabling the boot code on your
adapter.
• Emulex firmware files support both OneConnect and LightPulse adapters.
• For OneConnect adapters:
• Firmware and boot code are provided in a single flash image called a .UFI file.
• The UFI file contains all of the files that support all OneConnect adapters. The latest
files for your adapter are installed automatically when you use an Emulex utility to
update the firmware.
• The UFI file contains both firmware and boot code.
• For LightPulse adapters:
• Firmware is provided in a .ZIP file as a .ALL file or a .AWC file. You must manually unzip
the .ALL or .AWC file from the .ZIP file before you can use an Emulex utility to install it.
• Firmware differs between adapter models. Make sure you download the appropriate
firmware for your adapter.
• The .ZIP file may or may not include a boot code (.PRG) file.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
HBAnyware Release Notes
Information
Windows 2003-2008
Operating System
Manual
Version
2.20.006
Size Driver
44KB
File Name
windows_release_notes.pdf
Observations
Qualification:
Microsoft currently does not offer an FCoE WHQL "Certified for Windows" logo program. When the Storport Miniport driver is used with a standard Fibre Channel HBA, the driver is qualified for the "Certified for Windows" logo program. When the Storport MiniPort driver is used with an FCoE CNA, the driver is considered "unclassified" by Microsoft. In both cases, the Storport Miniport drivers are digitally signed by Microsoft and will be recognized by Windows Sever 2003, Windows Server 2008 and Windows Server 2008 R2. Note
For Windows Server 2003, SP2 and the KB932755 update to the Microsoft Storport driver are required. KB945119 is recommended. The Storport KB update must be applied before the Emulex Storport Miniport driver can be installed.
Tested Architectures:
x86
x64
IA64
New features, fixed issues and known issues in the HBAnyware utility
Release Notes
Date: September 2009
Product: HBAnyware® Utility and the Windows Drivers
Version: 4.1
This document describes the known issues associated with this utility build release. For the latest product
documentation, go to www.emulex.com. If you have any questions or require additional information, contact an
authorized Emulex Corporation technical representative.
New Features in HBAnyware Utility Version 4.1
1. Designed for adapter FCoE Initialization Protocol (FIP), subject to subsequent industry testing.
2. Supports CIM interface (operational name, target node WWN and flash contents program ID) for
VMware ESX 4i and VMware ESX 4.0 COS.
3. Virtual port and virtual machine mapping information is displayed.
New Resolved Issues in HBAnyware Utility Version 4.1
1. New - HBAnyware GUI is now available on the IA64 architecture.
It is no longer required to use the HbaCmd command line utility on an IA64 system.
2. All virtual port information did not appear if you manually resized the window.
3. Target information for a virtual port erroneously showed a LUN Masking tab.
4. Using HbaCmd, the change World Wide Name function did not check for physical targets for all inband
ports.
5. Using HbaCmd, the help message for the setauthconfig function erroneously stated that accepted values
were between 0 and 5. The accepted values are between 1 and 5.
6. Using HTTPS, a port number was not used for some functions if the restricthttptoloopback parameter
was set to false.
7. The internal and external loopback diagnostic tests were not available for LP21000 and LP21002
adapters.
Known Issues in HBAnyware Utility Version 4.1
1. The HBAnyware utility GUI application only launches from IBM Director version 5.1.
Workaround: There is no workaround at this time.
2. On LPe1105 adapters, diagnostic beaconing is available only if the adapter does not have VPD.
Workaround: There is no workaround at this time.
3. On LPe12000 adapters, volatile WWN changes may not be supported.
Workaround: Update firmware; see the Emulex Web site for more information.
Caution: Verify the version of OEM firmware to use based on OEM qualifications and support.
4. On LP21000 and LP21002 adapters, FIP mode may need to be disabled to bring a link up.
If you have upgraded to the new CEE firmware that supports FIP and connect the port to a switch with
firmware that does not support FIP, the port’s link will be down. If you plug a loopback plug into an
adapter port with FIP disabled, the link will be down.
Workaround: Disable FIP mode on the adapter port.
5. On Windows Vista platforms, the Add Range of Hosts feature in the HBAnyware utility is not
available.
Workaround: There is no workaround at this time.
6. If the HBAnyware CIM Client is used to access a VMware ESX server, up to 127 LUNs can be
displayed in the discovery-tree (numbered 0 to 126).
Workaround: There is no workaround at this time.
7. Not all adapters may appear in the discovery-tree.
Although the HBAnyware utility provides support for LightPulse adapters that are reprogrammed with
WWPNs outside the typical Emulex range (such as HP’s Virtual Connect for Fibre Channel on the
BladeSystem c-Class platform) not all adapters appear in the discovery-tree.
Workaround: The HBAnyware utility must be deployed across all servers on the SAN, as well as any
other management console used for out-of-band management, so that all adapters appear in the
discovery-tree.
8. Multiport adapter models are represented in the HBAnyware utility discovery-tree as
multiple adapters with a single port icon.
For older mulitport HBA models, the HBAnyware utility displays each port under individual adapter icons
in the discovery-tree. Newer multiport HBA models (LP9802 or later) are represented by a single adapter
icon that branches out to multiple port icons.
Workaround: There is no workaround at this time.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Driver Release Notes
Information
Windows 2003-2008
Operating System
Manual
Version
2.20.006
Size Driver
26KB
File Name
driver_release_notes_b.pdf
Observations
Qualification: Microsoft currently does not offer an FCoE WHQL "Certified for Windows" logo program. When the Storport Miniport driver is used with a standard Fibre Channel HBA, the driver is qualified for the "Certified for Windows" logo program. When the Storport MiniPort driver is used with an FCoE CNA, the driver is considered "unclassified" by Microsoft. In both cases, the Storport Miniport drivers are digitally signed by Microsoft and will be recognized by both Windows Sever 2003 and Windows Server 2008.
Note For Windows Server 2003, SP2 and Hotfix Q957910 update to the Microsoft STORPort driver are required. The STORPort KB update must be applied before the Emulex STORPort Miniport driver can be installed.
For Windows Server 2008, SP2 and Hotfix Q968675 update to the Microsoft STORPort driver are required. The STORPort KB update must be applied before the Emulex STORPort Miniport driver can be installed.
For Windows Server 2008 R2, no Hotfix is required
New features, fixed issues and known issues in the driver
New Features in Version 2.20.006
1. Added ExtTransferSize parameter. This parameter improves performance on tape devices supporting a larger block size.
2. Added support for Windows Server 2008 R2. This version of the driver kit adds support for Windows Server 2008 R2.
Resolved Issues in Version 2.20.006
1. There was the potential for the driver and the HBA to not synchronize properly, after the HBA was in warm start mode. Polling was modified in the HBAnyware utility.
2. The internal and external loopback diagnostic tests were not available for LP21000 and LP21002 adapters.
Known Issues in Version 2.20.006
1. The HBAnyware GUI is not available on the IA64 architecture. If you are installing on an IA64 system use the HBACMD command line utility, which is available in the Storport Miniport driver and core (CLI) application kit, instead of the Storport Miniport driver and HBAnyware kit.
Workaround: There is no workaround at this time.
2. Do not perform software-first installations on Windows Server 2008 or Vista systems. The procedure documented in the driver user manual might not have the expected effect. No error will be reported, but Windows might continue using the version of the driver distributed with the operating system rather than the new driver when an adapter is installed. The problem occurs because Microsoft-distributed drivers are versioned differently than Emulex- distributed drivers.
Workaround: There is no workaround at this time.
3. To revert to an older driver after a newer driver has been installed, you must uninstall all Emulex software and drivers before installing the older driver kit. Failure to do so could leave your system in an unsupported state. See the driver user manual for all the procedures you must follow.
Workaround: There is no workaround at this time.
4. Due to an issue with HBAnyware version 4.1, the default global driver parameters for converged network adapters (CNAs) cannot be changed.
Workaround: There is no workaround at this time.
Company
Emulex
Categories
Networks Cards
Serie
Emulex Products Emulex for Fujitsu
Model
Emulex LPe1150-F4-F
Description
Driver Kit
Operating System
Windows 2003-2008
Version
2.20.006
Size Driver
37.1MB
File Name
storportminiportkit_2.20.006-1h.exe
Observations
Qualification: Microsoft currently does not offer an FCoE WHQL "Certified for Windows" logo program. When the Storport Miniport driver is used with a standard Fibre Channel HBA, the driver is qualified for the "Certified for Windows" logo program. When the Storport MiniPort driver is used with an FCoE CNA, the driver is considered "unclassified" by Microsoft. In both cases, the Storport Miniport drivers are digitally signed by Microsoft and will be recognized by Windows Sever 2003, Windows Server 2008 and Windows Server 2008 R2.
Note For Windows Server 2003, SP2 and the KB932755 update to the Microsoft Storport driver are required. KB945119 is recommended. The Storport KB update must be applied before the Emulex Storport Miniport driver can be installed.
Tested Architectures: x86, x64, IA64
Base driver, HBAnyware utility 4.1a36 (37.1 MB exe file)
Access to Official Website Emulex
Welcome to the HelpDrivers, driver for printers.
Original files: In HelpDrivers, all drivers, manuals, BIOS, etc. are those originally provided by the official manufacturers. Click here to learn more
You can download by either clicking the 'Download' button. From the File Download window, verify that "Save" is selected and click OK.
Do not rename the file you're downloading, it may cause installation problems.