Available 3 files for Datadirect Networks S2A8000 Series
Select Files
Company
Datadirect Networks
Categories
Storage & Tape Backup
Model
Datadirect Networks S2A8000 Series
Description
Current 8x00 firmware release
Operating System
Firmware release
Size Driver
1.7MB
File Name
8k531.zip
Observations
DataDirect Networks Silicon Storage Appliance Model 8000
Firmware Version: 5.31
S2A 8000[1]: ?
Available Commands:
ALARM Functions pertaining to the AVR System Alarm.
APC_UPS Displays the status of the APC UPS trap monitor.
API Display/Change the enabling/disabling of API connections.
AV Displays information about the Audio/Visual settings.
CACHE Displays and adjusts the cache settings of the LUNs.
COMMENT Echoes a message to the screen and saves it to the LOG.
CONSOLE Displays/Changes the console settings of this unit.
DATE Displays/Changes the current system date.
DEBUG Enables/Disables the system debug messages.
DEFAULTS Restores the system to its default configuration.
DISK Displays information about the disks in the system.
DUAL Displays information about the dual system configuration.
EXIT Allows the user to log out of a CLI or Telnet session.
FAULTS Displays all current faults, warnings and errors in the system.
HELP Displays help information about system commands.
HOST Displays information about the host fibre channel ports.
LICENSE Displays/Changes the unit's current licensing information.
LOG Displays a log of previous system messages.
LOGIN Allows the user to log into a CLI or Telnet session.
LOGOUT Allows the user to log out of a CLI or Telnet session.
LUN Displays the status of, or Adds/Removes LUNs to/from the system.
MIRROR Displays/Changes Internal Mirrored Groups (IMG) in the system.
NETWORK Displays/Changes information on the system's network configuration.
PASSWORD Changes the CLI and Telnet usernames and passwords.
RESTART Performs a restart of the system.
ROUTE Displays/Updates information about the unit's IP routing table.
SAVE Saves the parameter blocks.
SES Displays all current disk enclosure faults.
SETTINGS Displays/Changes the CLI/Telnet session control settings.
SHOWALL Displays the output from a collection of essential CLI commands.
SHUTDOWN Performs a shutdown of the system.
SPARE Displays information about the spares in the system.
STATS Displays the system performance statistics.
TELNET Display/Change the enabling/disabling of remote Telnet sessions.
TFTP Performs an update of the firmware on the system using TFTP.
TIER Displays information about the tiers in the system.
TIME Displays/Changes the current system time.
UPTIME Displays the system's Uptime.
USER Displays/Changes the host and anonymous users' information.
VERSION Displays the firmware version of the system.
WHOAMI Displays the owner of the current CLI or Telnet session.
ZONING Displays and changes the default LUN zoning for each host port.
S2A 8000[1]: ? alarm
ALARM Functions pertaining to the AVR System Alarm.
This command controls the audible AVR system alarm.
[TEST]
Tests the AVR system alarm.
S2A 8000[1]: ? apc_ups
APC_UPS Displays the status of the APC UPS trap monitor.
This command is used to display the status of the APC UPS SNMP trap
monitor. The monitor may also be enabled or disabled by this command.
Any outstanding APC UPS traps may be also cleared through this command.
Note: The SNMP community string on the UPS should be set to S2A.
Company
Datadirect Networks
Categories
Storage & Tape Backup
Model
Datadirect Networks S2A8000 Series
Description
S2A 8x00 User Guide
Information
User Manual
Operating System
Manual
Size Driver
3.3MB
File Name
s2a-8000_userguide-9600125-4.pdf
Observations
Section 1: Introducing the S2A 8000/8500
1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1.1 DataDirect Networks’ SAN Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1.2 The S2A 8000/8500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1.3 Features of the S2A 8000/8500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 The S2A 8000/8500 System Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2.1 Power Supply and Fan Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.2.2 I/O Connectors and Status LED Indicators. . . . . . . . . . . . . . . . . . . . . . 9
1.2.3 Host and Disk Connectivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.2.4 Uninterruptible Power Supplies (UPS) . . . . . . . . . . . . . . . . . . . . . . . . 11
Section 2: Installing the S2A 8000/8500
2.1 Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.2 Setting Up the S2A 8000/8500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.2.1 Unpacking the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.2.2 Unpacking the S2A 8000/8500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.2.3 Rack-Mounting the S2A 8000/8500 Chassis. . . . . . . . . . . . . . . . . . . . . 20
2.2.4 Connecting the S2As in Dual Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.2.5 Connecting the S2A 8000/8500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.2.6 Selecting AL_PA for Your Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.7 Laying Out your Storage Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.8 Connecting the RS-232 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.2.9 Powering On the S2A 8000/8500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.3 Configuring the S2A 8000/8500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.3.1 Setup Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.3.2 Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.3.3 Accessing the Administrative Utility . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.3.4 Login as Administrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.3.5 Setting System Time & Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.3.6 Setting Tier Mapping Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.3.7 Verifying Connections for SF6016 Enclosures . . . . . . . . . . . . . . . . . . 34
Company
Datadirect Networks
Categories
Storage & Tape Backup
Model
Datadirect Networks S2A8000 Series
Description
TFTP Firmware Update Procedure
Information
User Manual
Operating System
Manual
Size Driver
68KB
File Name
s2a9xxx_tftp_instructions.pdf
Observations
The TFTP command enables the administrator to download the new S2A9900 firmware
from a TFTP server to the S2A9900. A TFTP server must be running when using this
command(can be any system on your local network). This command will “fail” the
current S2A9900 and should not be used during active I/O. Follow these steps if you need
to update the firmware files. NOTE : Before you begin upgrading the firmware, make
sure all access to S2A9900are stopped, all volumes on the storage array are unmounted
and allow sufficient time for the S2A9900 to flush all cached data
1. Collect and save the output of the following command before you update the firmware:
SHOWALL
2. Copy the new firmware file to your TFTP server (such as the directMONITOR
console).
3. Connect to the S2A9900 via Telnet.
4. Enter command TFTP.
5. You will be asked to confirm action (Figure 3-51). Type y to continue.
6. Then enter the TFTP server’s IP address.
7. Enter the firmware path and filename.
8. If you have the couplet S2A9900 configuration, connect and log into the other
S2A9900.
Repeat Steps [4] to [7] above to update the firmware.
9. Issue the RESTART command on the S2A9900 unit(s) to restart.
10. For dual mode only: After both S2A9900 are back on-line, use the DUAL command
to verify that both S2A9900 units are healthy. If either S2A9900 shows failed, login to
the healthy S2A9900 and issue the DUAL HEAL command.
Access to Official Website Datadirect Networks
Welcome to the HelpDrivers, driver for printers.
Original files: In HelpDrivers, all drivers, manuals, BIOS, etc. are those originally provided by the official manufacturers. Click here to learn more
You can download by either clicking the 'Download' button. From the File Download window, verify that "Save" is selected and click OK.
Do not rename the file you're downloading, it may cause installation problems.