Exsys EX-40032 Download Manual

Available 1 files for EX-40032
Company
Exsys
Categories
Other Peripherals
Model
Exsys EX-40032
Description
2S ISA Serial RS-232 card, 16-Bit
Operating Systems
Manual
Size Manual
233Kb
File Name
ex-40032.pdf
Info
DESCRIPTION & TECNICAL INFORMATION :
The EX-40032 16-Bit RS-232 serial card is equipped with two high-speed 16-Byte FIFO
16C550 port. The EX-40032 includes one external 9- and 25 pins D-SUB male connector
for attaching peripherals unit with standard RS-232 serial interface (Modem, Mouse,
Plotter etc.).
The EX-40032 serial card has an extended address decoder, which allows easy configuration
with all seven I/O addresses 3F8 (COM1), 2F8 (COM2), 3E8 (COM3), 2E8
(COM4), 250 (COM5), 258 (COM6) and 260 (COM7). In addition to the I/O addresses,
it’s possible to adding eleven interrupts (IRQ 3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15). The
serial ports can be disabled (DIS).
CONFIGURATION:
The EX-40032 16-Bit serial card must be configured, before is installed into a computer
system. Never Use the same I/O address and Interrupt with more than one port.
Jumper are used to configure the card according to the system environment. With the
Jumper “DIS” you can disabled the I/O addresses. The following table shows the standard
factory settings.
JUMPER SETTING & CONNECTORS:
The EX-40032 give you the possibility configure +5V or +12V to the four different pins
from the 9 pin (S1) and (S2) male connector :
Attention !! The jumpers for +5Volt or +12Volt are set from the factory to disable. For
normal use never change the jumper.

DRIVER INSTALLATION :
Windows 9x/ME/2000/XP & Vista:
Start Windows 2000 / XP and click to >Start< >Setting< >Control Panel< >Add/Remove
Hardware< >Next<. Mark >Add/Troubleshoot a Device< and click >Next<. Mark >Add
a new device< and click >Next<. Mark >Yes, search for new hardware<. Click to
>Next<. Windows 2000 / XP give now following information to the screen „Detected
hardware“ „Install Communications Port“. Click to >Next< and >Finish<.
The EX-40032 is now configured with COM3 and COM4 in the Device-Manager.
CHECK THE INSTALLED DRIVER:
Click at Start<>Run< then enter “compmgmt.msc“ and click at >OK<. In the windows
that open select >Device Manager<. Under ”Ports (COM and LPT)“ you should find one
or more new ”PCI Ports“ as sample (COM3). If you see this or similar entries the card is
installed correctly.
CHANGE PORT NUMBER:
If you like to change the port number for example COM 3 to COM5, open the >Device
Manager< click at >COM3<, >Settings< and then >Advance<. There you can change
between COM 3 to 256.
Windows NT 4.0:
Start Windows NT 4.0. The operating system will install automatically the EX-40032 with
COM3 and COM4. This you can check if you click to >Start< >Setting< >Control Panel<
>Ports<. You must see then the setting COM3 and COM4. You can check the EX-40032
also under NT-Diagnostic. Klick to. >Start< >Programs< >Administrative Tools
[Common]< >Windows NT-Diagnostics< after you click to >Resource< >IRQ<. You can
see then the setting „03E8-03EE Serial 0 ISA“ and „02E8-02EE Serial 0 ISA.
HelpDrivers Since March 2000