LSI MegaRaid Sata 300-8X Download Drivers

Available 5 files for MegaRaid Sata 300-8X
Company
LSI
Categories
HD Controller & Removable drive
Model
LSI MegaRaid Sata 300-8X
Description
Drivers
Operating Systems
MS-Dos
Version Driver
2.08
Size Driver
15Kb
File Name
dr_dos_2.08.zip
Info
Supported Controllers:
================

8 LD controllers
MegaRAID SCSI Express 000
MegaRAID SCSI Express 100
MegaRAID SCSI Express 200
MegaRAID SCSI Express 300
MegaRAID SCSI Enterprise 1200
MegaRAID SCSI Enterprise 1300
MegaRAID SCSI Enterprise 1400
MegaRAID SCSI Enterprise 1500

40 LD controllers
MegaRAID SCSI Enterprise 1600
MegaRAID SCSI Express 500
MegaRAID SCSI Elite 1600
MegaRAID SCSI Elite 1650
MegaRAID SCSI 320-0
MegaRAID SCSI 320-1
MegaRAID SCSI 320-2
MegaRAID SCSI 320-0X
MegaRAID SCSI 320-2X
MegaRAID SCSI 320-4X
MegaRAID SCSI 320-2E
MegaRAID SATA 150-4
MegaRAID SATA 150-6
MegaRAID SATA 300-4x
MegaRAID SATA 300-8x
MegaRAID PCI Express(TM) ROMB

Component:
==========
DOS SCSI MegaRAID Driver, Version 2.08
Release Date: 12/15/2004
Products Supported: MegaRAID Controllers

Version Numbers:
Component Current Version Previous Version
=============== ================
MEGASPI.SYS 2.08 (12/15/04) 2.07 (01/30/04)
Bug Fixes: 1
==========

1. Fixed Megaspi.sys hangs when no controller is installed

Enhancements: 1
=============

1. NONE

Component Features: 0
===================

1 NONE

Known Restrictions: 2
===================

1. The driver doesn't support multiple 428 controllers in BBS system. But it supports MULTIPLE 428 controller(s) in Non BBS system. This is because 428 BIOS doesn't have a support for BBS

2. If the user disables PCI Option ROM for 471-series adapter then ASPI Driver will NOT initialize it and it will not provide support.
Company
LSI
Categories
HD Controller & Removable drive
Model
LSI MegaRaid Sata 300-8X
Description
Drivers
Operating Systems
Windows 2000
Version Driver
5.49
Size Driver
41Kb
File Name
dr_signed_driver_5.49_6.45.2.32.zip
Info
[Version]
Signature="$WINDOWS NT$"
Class=System
ClassGuid={4D36E97D-E325-11CE-BFC1-08002BE10318}
Provider=%LSI%
CatalogFile=megaraid.cat
CatalogFile.ntx86=megaraid.cat
DriverVer=08/02/2004,5.49
;DriverVer=08/02/2004,6.45.2.32

[ControlFlags]
ExcludeFromSelect = *
[SourceDisksNames]
[SourceDisksFiles]
[Manufacturer]
%LSI%=LSI, NT.5.1, NT.5.2
%DELL%=DELL
%TOSHIBA%=TOSHIBA
%HP%=HP
%JMR%=JMR
%NSTOR%=NSTOR
%GATEWAY%=GATEWAY
%NEC%=NEC
%ESG-SHV%=ESG-SHV

[LSI]
%NULL.DeviceDesc% = NODRV, SCSI\Other__RAID___DummyDevice____05XX
%AMIProcessor% = NODRV, SCSI\ProcessorAMI_____MegaProcessor___
%AMI906Processor% = NODRV, SCSI\ProcessorAMI_____Series_906______
%LSIProcessor% = NODRV, SCSI\ProcessorLSI_____MegaProcessor___
%LSI320Processor% = NODRV, SCSI\ProcessorLSI_____SCSI_320-2______
%LSI3200Processor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-0X_
%LSI3202xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2X_
%LSI3204xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-4X_
%LSI3202EProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2E_
%IDEProcessor% = NODRV, SCSI\ProcessorLSI_____IDE_SAF-TE__-AMI
%AMI523Processor% = NODRV, SCSI\ProcessorAMI_____BackPlane944____
%QuantaProcessor% = NODRV, SCSI\ProcessorGENERIC_SATA_BP_________

;Qlogic Chip
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8471101E
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8493101E

[LSI.NT.5.1]
%NULL.DeviceDesc% = XPDRV, SCSI\Other__RAID___DummyDevice____05XX
%AMIProcessor% = XPDRV, SCSI\ProcessorAMI_____MegaProcessor___
%AMI906Processor% = XPDRV, SCSI\ProcessorAMI_____Series_906______
%LSIProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaProcessor___
%LSI320Processor% = XPDRV, SCSI\ProcessorLSI_____SCSI_320-2______
%LSI3200Processor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-0X_
%LSI3202xProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-2X_
%LSI3204xProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-4X_
%LSI3202EProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-2E_
%IDEProcessor% = XPDRV, SCSI\ProcessorLSI_____IDE_SAF-TE__-AMI
%AMI523Processor% = XPDRV, SCSI\ProcessorAMI_____BackPlane944____
%QuantaProcessor% = XPDRV, SCSI\ProcessorGENERIC_SATA_BP_________

;Qlogic Chip
%virtual.DeviceDesc% = XPDRV, PCI\VEN_1077&DEV_1216&SUBSYS_8471101E
%virtual.DeviceDesc% = XPDRV, PCI\VEN_1077&DEV_1216&SUBSYS_8493101E
Company
LSI
Categories
HD Controller & Removable drive
Model
LSI MegaRaid Sata 300-8X
Description
Drivers
Operating Systems
Windows 2003
Version Driver
6.45.2.32
Size Driver
41Kb
File Name
dr_signed_driver_5.49_6.45.2.32.zip
Info
[Version]
Signature="$WINDOWS NT$"
Class=System
ClassGuid={4D36E97D-E325-11CE-BFC1-08002BE10318}
Provider=%LSI%
CatalogFile=megaraid.cat
CatalogFile.ntx86=megaraid.cat
DriverVer=08/02/2004,5.49
;DriverVer=08/02/2004,6.45.2.32

[ControlFlags]
ExcludeFromSelect = *
[SourceDisksNames]
[SourceDisksFiles]
[Manufacturer]
%LSI%=LSI, NT.5.1, NT.5.2
%DELL%=DELL
%TOSHIBA%=TOSHIBA
%HP%=HP
%JMR%=JMR
%NSTOR%=NSTOR
%GATEWAY%=GATEWAY
%NEC%=NEC
%ESG-SHV%=ESG-SHV

[LSI]
%NULL.DeviceDesc% = NODRV, SCSI\Other__RAID___DummyDevice____05XX
%AMIProcessor% = NODRV, SCSI\ProcessorAMI_____MegaProcessor___
%AMI906Processor% = NODRV, SCSI\ProcessorAMI_____Series_906______
%LSIProcessor% = NODRV, SCSI\ProcessorLSI_____MegaProcessor___
%LSI320Processor% = NODRV, SCSI\ProcessorLSI_____SCSI_320-2______
%LSI3200Processor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-0X_
%LSI3202xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2X_
%LSI3204xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-4X_
%LSI3202EProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2E_
%IDEProcessor% = NODRV, SCSI\ProcessorLSI_____IDE_SAF-TE__-AMI
%AMI523Processor% = NODRV, SCSI\ProcessorAMI_____BackPlane944____
%QuantaProcessor% = NODRV, SCSI\ProcessorGENERIC_SATA_BP_________

;Qlogic Chip
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8471101E
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8493101E

[LSI.NT.5.1]
%NULL.DeviceDesc% = XPDRV, SCSI\Other__RAID___DummyDevice____05XX
%AMIProcessor% = XPDRV, SCSI\ProcessorAMI_____MegaProcessor___
%AMI906Processor% = XPDRV, SCSI\ProcessorAMI_____Series_906______
%LSIProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaProcessor___
%LSI320Processor% = XPDRV, SCSI\ProcessorLSI_____SCSI_320-2______
%LSI3200Processor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-0X_
%LSI3202xProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-2X_
%LSI3204xProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-4X_
%LSI3202EProcessor% = XPDRV, SCSI\ProcessorLSI_____MegaRAID_320-2E_
%IDEProcessor% = XPDRV, SCSI\ProcessorLSI_____IDE_SAF-TE__-AMI
%AMI523Processor% = XPDRV, SCSI\ProcessorAMI_____BackPlane944____
%QuantaProcessor% = XPDRV, SCSI\ProcessorGENERIC_SATA_BP_________

;Qlogic Chip
%virtual.DeviceDesc% = XPDRV, PCI\VEN_1077&DEV_1216&SUBSYS_8471101E
%virtual.DeviceDesc% = XPDRV, PCI\VEN_1077&DEV_1216&SUBSYS_8493101E
Company
LSI
Categories
HD Controller & Removable drive
Model
LSI MegaRaid Sata 300-8X
Description
Drivers
Operating Systems
Windows Server 2003 (64 bit)
Version Driver
6.45.3.64
Size Driver
27Kb
File Name
sdr_6.45.3.64.zip
Info
[Version]
Signature="$WINDOWS NT$"
Class=System
ClassGuid={4D36E97D-E325-11CE-BFC1-08002BE10318}
Provider=%LSI%
CatalogFile=MRAID64.cat
DriverVer=08/18/2004,6.45.3.64

[ControlFlags]
ExcludeFromSelect = *
[SourceDisksNames]
[SourceDisksFiles]
[Manufacturer]
%LSI%=LSI,NTamd64
%DELL%=DELL, NTamd64
%TOSHIBA%=TOSHIBA, NTamd64
%HP%=HP, NTamd64
%JMR%=JMR, NTamd64
%NSTOR%=NSTOR, NTamd64
%GATEWAY%=GATEWAY, NTamd64
%NEC%=NEC, NTamd64
%ESG-SHV%=ESG-SHV, NTamd64

[LSI.NTamd64]
%NULL.DeviceDesc% = NODRV, SCSI\Other__RAID___DummyDevice____
%AMIProcessor% = NODRV, SCSI\ProcessorAMI_____MegaProcessor___
%AMI906Processor% = NODRV, SCSI\ProcessorAMI_____Series_906______
%LSIProcessor% = NODRV, SCSI\ProcessorLSI_____MegaProcessor___
%LSI320Processor% = NODRV, SCSI\ProcessorLSI_____SCSI_320-2______
%LSI3202xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2X_
%LSI3204xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-4X_
%LSI3202EProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2E_
%IDEProcessor% = NODRV, SCSI\ProcessorLSI_____IDE_SAF-TE__-AMI
%AMI523Processor% = NODRV, SCSI\ProcessorAMI_____BackPlane944____

;Qlogic Chip
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8471101E
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8493101E

[HP.NTamd64]
%HPProcessor.DeviceDesc% = NODRV, SCSI\ProcessorSDR_____GEM318__________
%HP2MProcessor.DeviceDesc% = NODRV, SCSI\ProcessorHP______NETRAID-2M______

[ESG-SHV.NTamd64]
%ESG-SHVProcessor% = NODRV, SCSI\ProcessorESG-SHV_SCA_HSBP_M9_____
%ESG-SHVProcessor% = NODRV, SCSI\ProcessorESG-SHV_SCA_HSBP_M13____

[NEC.NTamd64]
%NECProcessor% = NODRV, SCSI\ProcessorNEC_____GEM312R2________

[NSTOR.NTamd64]
%NSTORProcessor% = NODRV, SCSI\ProcessornStor___CR8L__SAF-TE1.05
%MEGARAIDSAFTEProcessor% = NODRV, SCSI\ProcessorMegaRAIDAMI___SAF-TE1.05
[DELL.NTamd64]
;DELL Processor device
%DELLProcessor% = NODRV, SCSI\ProcessorDELL____PERC_2/DC_______
%DELLSCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_2/SC_______
%DELLDCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_3/DC_______
%DELLQCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_3/QC_______
%DELLDiProcessor% = NODRV, SCSI\ProcessorDELL____PERC_4/Di_______
%DELL4DCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_4/DC_______
%DELL4EDCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_4e/DC______
Company
LSI
Categories
HD Controller & Removable drive
Model
LSI MegaRaid Sata 300-8X
Description
Drivers
Operating Systems
Windows XP
Version Driver
6.45
Size Driver
59Kb
File Name
dr_xp_6.45_3.zip
Info
[Version]
Signature="$WINDOWS NT$"
Class=System
ClassGuid={4D36E97D-E325-11CE-BFC1-08002BE10318}
Provider=%LSI%
CatalogFile=MRAID32.cat
DriverVer=08/02/2004,6.45.32

[ControlFlags]
ExcludeFromSelect = *
[SourceDisksNames]
[SourceDisksFiles]
[Manufacturer]
%LSI%=LSI
%DELL%=DELL
%TOSHIBA%=TOSHIBA
%HP%=HP
%JMR%=JMR
%NSTOR%=NSTOR
%GATEWAY%=GATEWAY
%NEC%=NEC
%ESG-SHV%=ESG-SHV

[LSI]
%NULL.DeviceDesc% = NODRV, SCSI\Other__RAID___DummyDevice____
%AMIProcessor% = NODRV, SCSI\ProcessorAMI_____MegaProcessor___
%AMI906Processor% = NODRV, SCSI\ProcessorAMI_____Series_906______
%LSIProcessor% = NODRV, SCSI\ProcessorLSI_____MegaProcessor___
%LSI320Processor% = NODRV, SCSI\ProcessorLSI_____SCSI_320-2______
%LSI3202xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2X_
%LSI3204xProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-4X_
%LSI3202EProcessor% = NODRV, SCSI\ProcessorLSI_____MegaRAID_320-2E_
%IDEProcessor% = NODRV, SCSI\ProcessorLSI_____IDE_SAF-TE__-AMI
%AMI523Processor% = NODRV, SCSI\ProcessorAMI_____BackPlane944____
%QuantaProcessor% = NODRV, SCSI\ProcessorGENERIC_SATA_BP_________

;Qlogic Chip
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8471101E
%virtual.DeviceDesc% = NODRV, PCI\VEN_1077&DEV_1216&SUBSYS_8493101E

[HP]
%HPProcessor.DeviceDesc% = NODRV, SCSI\ProcessorSDR_____GEM318__________
%HP2MProcessor.DeviceDesc% = NODRV, SCSI\ProcessorHP______NETRAID-2M______

[ESG-SHV]
%ESG-SHVProcessor% = NODRV, SCSI\ProcessorESG-SHV_SCA_HSBP_M9_____
%ESG-SHVProcessor% = NODRV, SCSI\ProcessorESG-SHV_SCA_HSBP_M13____

[NEC]
%NECProcessor% = NODRV, SCSI\ProcessorNEC_____GEM312R2________

[NSTOR]
%NSTORProcessor% = NODRV, SCSI\ProcessornStor___CR8L__SAF-TE1.05
%MEGARAIDSAFTEProcessor% = NODRV, SCSI\ProcessorMegaRAIDAMI___SAF-TE1.05
[DELL]
;DELL Processor device
%DELLProcessor% = NODRV, SCSI\ProcessorDELL____PERC_2/DC_______
%DELLSCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_2/SC_______
%DELLDCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_3/DC_______
%DELLQCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_3/QC_______
%DELLDiProcessor% = NODRV, SCSI\ProcessorDELL____PERC_4/Di_______
%DELL4DCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_4/DC_______
%DELL4EDCProcessor% = NODRV, SCSI\ProcessorDELL____PERC_4e/DC______
HelpDrivers Since March 2000